5402 Tower Rd
Tallahassee, FL 32303
850-562-3132

Local Reviews
for saint george island, fl

Rated 5.0 out of 5 stars based on 6 customer reviews

  • Overall Experience
  • Quality
  • Price
  • Convenience

Le is why we use Benson's. Nuff Sed!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great

  • Overall Experience
  • Quality
  • Price
  • Convenience

Very thorough and professional

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great Tech

  • Overall Experience
  • Quality
  • Price
  • Convenience

Technicians did a good job. Polite and courteous..

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for saint george island, fl

Bryce D.

Bryce D. Job Checkin

Today I arrived on site and performed a winter time maintenance on your HVAC equipment. **Indoor Unit (Air Handler in Closet):** * Checked pleated 1" filter (20x20x1), condition fair. * Indoor coil condition fair and clean. **Outdoor Unit (Heat Pump on Side of House):** * Outdoor coil condition fair and clean. * Tested and inspected electrical components: blower motor, heat strip kit, condenser fan motor, compressor, compressor run capacitor, fan run capacitor, contactor, and electrical wiring; all working properly within manufacturer's specs. * Inspected blower wheel, primary drain pan, and secured electrical wires; all in good condition and working properly. **System Performance:** * Return air temperature: 82.0°F/85°F. * Supply air temperature: 113.3°F/110.6°F. * Cleared condensate drain line, cleaned out primary pan, and tested safety switch. **Additional Actions:** * Dusted the thermostat and restored power to the units. * Tested thermostat operation.


Liam S.

Liam S. Job Checkin

Today, I arrived on site to conduct a routine service check on the HVAC system. System Overview: * The HVAC system is functioning within normal parameters. * No unusual noises or odors detected during operation. Maintenance Performed: * Cleaned and replaced air filters to improve air quality. * Inspected ductwork for any potential leaks or blockages. * Checked thermostat settings and calibrated for optimal performance. * Verified refrigerant levels and ensured proper pressure in the system. Observations: * Indoor air quality is satisfactory, with no signs of humidity issues. * All electrical connections are secure and free from corrosion. * Ventilation is adequate, with airflow distributed evenly throughout the space. Customer Interaction: * Discussed system performance with the client, who expressed satisfaction. * Answered questions regarding maintenance needs and frequency. Recommendations: * Suggested regular filter changes every three months to maintain efficiency. * Advised


Liam S.

Liam S. Job Checkin

Today, I arrived on site and performed a summer time maintenance on your HVAC equipment. Here is a summary of my findings: Overall Equipment Condition: - Good Indoor Unit: - Location: Closet - Type: Air Handler - Picture: [Provide picture if available] Area Unit Services: - Upstairs/ downstairs Filtration: - Pleated 1" - Checked today Filter: - Size: 20x20x1 - Picture: [Provide picture if available] Condition of Indoor Coil: - Good - Clean Outdoor Unit: - Location: Side of House - Type: Heat Pump - Picture: [Provide picture if available] Condition of Outdoor Coil: - Good - Clean Tested and inspected electrical components: - Blower Motor - Condenser Fan Motor - Compressor - Blower Run Capacitor - Compressor Run Capacitor - Fan Run Capacitor - Contactor - Defrost Control Board - Electrical Wiring Inspected components in good condition and working properly: - Blower Wheel - Electrical Wires Secured - Primary Drain Pan Tested and cleared condensate drain system: - Cleared Drain Line - Clea


Aidan D.

Aidan D. Job Checkin

Today, I arrived on site and performed a summer time maintenance on your HVAC equipment. Here is a summary of my findings: Overall Equipment Condition: - Good Indoor Unit: - Location: Closet - Type: Air Handler - Picture: [Provide picture if available] Area Unit Services: - Upstairs/ downstairs Filtration: - Pleated 1" - Checked today Filter: - Size: 20x20x1 - Picture: [Provide picture if available] Condition of Indoor Coil: - Good - Clean Outdoor Unit: - Location: Side of House - Type: Heat Pump - Picture: [Provide picture if available] Condition of Outdoor Coil: - Good - Clean Tested and inspected electrical components: - Blower Motor - Condenser Fan Motor - Compressor - Blower Run Capacitor - Compressor Run Capacitor - Fan Run Capacitor - Contactor - Defrost Control Board - Electrical Wiring Inspected components in good condition and working properly: - Blower Wheel - Electrical Wires Secured - Primary Drain Pan Tested and cleared condensate drain system: - Cleared Drain


Emonte  O.

Emonte O. Job Checkin

Today we performed a summer time tune up on your unit,everything is working properly at this time .Thank you for your business. Tallahassee FL View visual findings from this job here - https://visionshare.xoi.io/?id=XA-A4F4-D7A158A4898841FFA89C621FF53C858A